Related Experiment Video
Updated: Oct 11, 2025

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
A gas chromatography-mass spectrometry method for quantifying squalane and squalene in aerosol emissions of
Elizabeth A Cowan1, Hang Tran1, Naudia Gray1
1Tobacco and Volatiles Branch, Division of Laboratory Sciences, National Center for Environmental Health, U.S. Centers for Disease Control and Prevention, 4770 Buford Hwy, Atlanta, Ga, 30341, United States.
Abstract:
Numerous chemicals of unknown inhalational toxicity have been measured in electronic cigarette, or vaping, products (EVPs). In addition, little is known about the liquid-to-aerosol transmission and deliveries of these chemicals, including oil-like terpenes such as squalene (SQE) and squalane (SQA). To provide information on the aerosol deliveries of these compounds from EVPs, we developed and validated a quantitative method to measure squalene and squalane in EVP aerosol emissions. Validation parameters include measurement repeatability (SQA and SQE %RSD <6%), intermediate precision (SQA: %RSD 11%, SQE: %RSD 17%), accuracy (SQA: 86-107%, SQE: 104-113%), matrix effects, method robustness, and analyte stability. Limits of detection were 6.06 ng/mL puffed air volume for both squalene and squalane. The method was used to measure squalene and squalane in aerosol emissions of 153 EVPs associated with case patients from a recent outbreak of e-cigarette, or vaping, product use associated lung injury (EVALI). The EVPs analyzed were organized into nicotine, cannabidiol, and tetrahydrocannabinol products by the percentage of nicotine, cannabidiol, and tetrahydrocannabinol in total particulate matter after vaping. In case-associated tetrahydrocannabinol products the detection rates and mean concentrations were 82.4% and 33.0 ng/mL puffed air for squalene and 4.41% and 7.80 ng/mL puffed air for squalane.
More Related Videos
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Absorption Spectroscopy: Atomization Methods
Volatilization
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....