Related Experiment Video
Updated: Oct 10, 2025

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Microchromatography integrated with impedance sensor for bioprocess optimization: Experimental and numerical study of
Amin Javidanbardan1, Virginia Chu2, João P Conde3
1IBB - Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal; Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.
Abstract:
In the last decade, there has been a growing interest in developing microfluidic systems as new scale-down models for accelerated and cost-effective biopharmaceutical process development. Nonetheless, the research in this field is still in its infancy and requires further investigation to simplify and accelerate the microfabrication process. In addition, integration of different label-free sensors into the microcolumn systems has utmost importance to minimize result discrepancies during the scale-up process. In this study, we developed a simple, low-cost integrated microcolumn (26 µl). Micromilling technology was employed to define the geometry and shape of microfluidic structures using poly(methylmethacrylate) (PMMA). The design of PMMA microstructure was transferred to polydimethylsiloxane (PDMS), and interdigitated planar microelectrodes (IDE) were integrated into the system. To evaluate the scalability of the developed microcolumn column, column performance was assessed and compared with a conventional 1-ml prepacked column. Computational Fluid Dynamics (CFD) studies were performed for both columns to understand the differences between theoretical and experimental results regarding retention time and peak broadening. Despite obtaining an acceptable asymmetric factor for the microcolumn (1.03 ± 0.02), the reduced plate height value was still higher than the recommended range with the value of 4.14 ± 0.18. Nevertheless, the consistency and significant improvement of microcolumn efficiency compared to previous studies provide the possibility of developing robust simulation tools for transferring acquired experimental data for larger-scale units.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: