Related Experiment Video
Updated: Oct 10, 2025

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
LSTM-only Model for Low-complexity HR Estimation from Wrist PPG
Abstract:
Continuous and non-invasive cardiovascular monitoring has gained attention due to the miniaturization of wearable devices. Particularly, wrist-worn photoplethysmography (PPG) sensors present an alternative to electrocardiogram recording for heart rate (HR) monitoring as it is cheaper and non-intrusive for daily activities. Yet, the accuracy of PPG measurements is heavily affected by motion artifacts which are inherent to ambulatory environments. In this paper, we propose a low-complexity LSTM-only neural network for HR estimation from a single PPG channel during intense physical activity. This work explored the trade-off between model complexity and accuracy by exploring different model dataflows, number of layers, and number of training epochs to capture the intrinsic time-dependency between PPG samples. The best model achieves a mean absolute error of 4.47 ± 3.68 bpm when evaluated on 12 IEEE SPC subjects.Clinical relevance- This work aims to improve the quality of HR inference from PPG signals using neural network, enabling continuous vital signal monitoring with little interference in daily activities from embedded monitoring devices.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:

