Ear and Finger PPG Wearables for Night and Day Beat-to-Beat Interval Detection
Summary
Earbud photoplethysmography (PPG) offers superior inter-beat interval (IBI) detection and estimation accuracy compared to finger-based PPG. Performance is enhanced during sleep, and a novel fusion scheme further improves results.
Area of Science:
- Biomedical Engineering
- Physiological Monitoring
- Wearable Technology
Background:
- Photoplethysmography (PPG) is a non-invasive optical technique used to measure blood volume changes.
- Inter-beat interval (IBI) estimation from PPG is crucial for cardiovascular health monitoring.
- Electrocardiography (ECG) provides R-to-R interval (RRI) as a gold standard for heart rate variability analysis.
Purpose of the Study:
- To compare the accuracy of ear and finger PPG for IBI detection and estimation against ECG-derived RRI.
- To evaluate the impact of sleep versus wake states on PPG-based IBI accuracy.
- To introduce and validate a novel fusion scheme combining ear and finger PPG data.
Main Methods:
- Simultaneous data acquisition using earbud PPG, ring PPG, and ECG devices on seven male subjects.
- Analysis of 43 recordings totaling over 72 hours, encompassing both sleep and wake states.
- Development and testing of a fusion algorithm integrating IBI data from both PPG devices.
Main Results:
- Earbud PPG demonstrated a higher beat detection rate and more accurate IBI estimation than ring PPG.
- PPG-based IBI detection and estimation performance were significantly better during sleep compared to wake states.
- The proposed fusion scheme achieved a 99.22% beat detection rate with Mean Absolute Error (MAE) of 7.42 ms and Root Mean Square Error (RMSE) of 13.45 ms.
Conclusions:
- Earbud PPG is a more accurate method for IBI estimation than finger PPG.
- Sleep state enhances the performance of PPG-based IBI monitoring.
- The novel fusion scheme offers a robust and accurate approach for PPG-based cardiovascular monitoring.
More Related Videos
Related Concept Videos
Pulse rhythm
982
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
982
Pulse Oximetry
949
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
949
Special considerations while measuring pulse
670
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
670
Holter Monitor: 24-Hour Monitoring
420
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
420
Equipments Used To Measure Blood Pressure
2.6K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.6K
Pulse Assessment Sites
1.6K
Pulse assessment sites are crucial in evaluating a patient's cardiovascular health. By assessing the pulsations of arteries at specific anatomical locations, healthcare professionals can gather valuable information about blood flow, heart rate, and peripheral circulation. Understanding these pulse assessment sites is essential for conducting comprehensive cardiovascular evaluations and monitoring patients' overall health. These sites are strategically chosen due to the accessibility and...
1.6K