Related Experiment Video

Updated: Oct 10, 2025

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
05:57

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique

Published on: January 6, 2023

2.7K

Kinematic and Workspace Analysis of the Master Robot in the Sinaflex Robotic Telesurgery System

Mehrnaz Aghanouri, Pejhman Kheradmand, Milad Mousavi

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |December 11, 2021
    PubMed

    Abstract:

    Robotic telesurgery systems, including master and slave robots, have emerged in recent years to provide benefits for both surgeons and patients. Surgeons use the master manipulator to navigate the slave robot. The Sinaflex telesurgery system introduced recently by Sina Robotics and Medical Innovators Co., Ltd. consists of two main subsystems: master robotic surgery console and slave surgery robots. As the surgeon use the master robot's handles to control the slave surgery robots, it is important for the master robot to provide the ergonomic postures for the surgeon and also providing a large enough workspace and good manipulability for the surgeon to control it. So in this paper, workspace, manipulability and isotropy of each handle at the master robot of the Sinaflex telesurgery system are analyzed. To this end, the kinematic of the master manipulator is derived, and its Jacobian is calculated. Using the simulation environment, the workspace of the master handle is obtained and drawn. The manipulability of the robot for each points of the workspace is computed. According to the results attained from the simulation study, the most manipulability values lie between 0.1 and 0.9 where it is greater than 0.44 for more than 50% of the whole workspace points of the end effector, which is as large as 574×484×560 mm.

    More Related Videos

    A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
    06:24

    A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement

    Published on: May 11, 2020

    9.0K
    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound
    07:41

    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound

    Published on: January 7, 2019

    9.3K

    Related Experiment Videos

    Last Updated: Oct 10, 2025

    A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
    05:57

    A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique

    Published on: January 6, 2023

    2.7K
    A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
    06:24

    A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement

    Published on: May 11, 2020

    9.0K
    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound
    07:41

    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound

    Published on: January 7, 2019

    9.3K

    Related Concept Videos

    Relative Motion Analysis using Rotating Axes-Problem Solving01:29

    Relative Motion Analysis using Rotating Axes-Problem Solving

    472
    Consider a crane whose telescopic boom rotates with an angular velocity of 0.04 rad/s and angular acceleration of 0.02 rad/s2. Along with the rotation, the boom also extends linearly with a uniform speed of 5 m/s. The extension of the boom is measured at point D, which is measured with respect to the fixed point C on the other end of the boom. For the given instant, the distance between points C and D is 60 meters.
    Here, in order to determine the magnitude of velocity and acceleration for point...
    472
    Relative Motion Analysis using Rotating Axes01:25

    Relative Motion Analysis using Rotating Axes

    582
    Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame.
    However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
    582

    Articles linked to this work by shared authors, journal, and citation graph.

    A Comparative Analysis of TIRADS and ATA Classification Systems in Determining the Malignancy of Thyroid Nodules.

    Cancer investigation·2026

    Evaluating the Sina flex robotic telesurgery system for fallopian tube-like procedures: A canine uterine horn model feasibility study.

    Journal of robotic surgery·2026

    Continuum-Spectral Modeling of Surface Roughness in Electron-Beam-Deposited GO/Ag Nanocomposite Thin Films.

    Nanomaterials (Basel, Switzerland)·2026

    Comprehensive Comparison of Features of Robotic Surgery Systems in Abdominal Surgeries: A Narrative Review Study.

    Health science reports·2026

    Moving beyond the hospital: in-depth characterization of daily-life mobility in patients with atypical Parkinsonian disorders.

    NPJ Parkinson's disease·2026

    Dynamic Modelling of the Surgery Arm in Sinaflex Robotic Telesurgery System.

    The international journal of medical robotics + computer assisted surgery : MRCAS·2025

    Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    From Scope to Scalpel: A Review of the Timing and Outcomes of Conversion in Minimally Invasive Liver Resections.

    Chirurgia (Bucharest, Romania : 1990)·2026

    Robotic Palpation for Spatiotemporal Arterial Pulse Quantification and Mapping Using Multilevel Microdome-Based Soft Pressure Sensors.

    Small (Weinheim an der Bergstrasse, Germany)·2026

    A Preclinical Multifunctional Capsule Robot with Unified Diagnosis and Targeted Thermal Therapy for Gastrointestinal Diseases.

    Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026

    Iterative trocar-constrained laparoscope viewpoint search for enhanced surface coverage in 3D reconstruction.

    Scientific reports·2026

    Robot-assisted CT-guided interventions: Where are we now and where are we going?

    European radiology·2026

    A multi-constraint gradient coil optimization method based on an improved MOEA/D.

    Journal of magnetic resonance (San Diego, Calif. : 1997)·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us