Time-Sensitive Aspects of Mars Sample Return (MSR) Science

Nicholas J Tosca1, Carl B Agee2, Charles S Cockell3

  • 1University of Cambridge, Department of Earth Sciences, Cambridge, UK.

Astrobiology
|December 14, 2021
PubMed

Insights

Mars Sample Return (MSR) science is time-sensitive due to rapid degradation of organic materials and volatile exchange. Investigations must occur within the Sample Receiving Facility (SRF) to preserve critical scientific data.

Area of Science:

  • Planetary Science
  • Astrobiology
  • Geochemistry

Background:

  • Samples returned from Mars require quarantine in a Sample Receiving Facility (SRF) for safety assessment before further study.
  • Sample handling, including seal breaching and headspace gas extraction, can initiate irreversible, time-dependent processes.
  • Four key processes (organic degradation, gas composition modification, mineral-volatile exchange, redox-sensitive material alteration) threaten scientific integrity.

Purpose of the Study:

  • To identify and characterize time-sensitive processes affecting Mars returned samples.
  • To recommend strategies for sample preparation and analysis within the SRF to mitigate data loss.
  • To guide future research on quantifying volatile exchange and developing stabilization techniques.

Main Methods:

  • Analysis of time-dependent processes affecting organic compounds, gas composition, mineralogy, and redox-sensitive materials.
  • Evaluation of timescales for degradation, volatile loss, and mineralogical transformation.
  • Development of recommendations for SRF capabilities, sample preparation, and analytical instrumentation.

Main Results:

  • Organic materials, especially biomolecules, are susceptible to rapid degradation, accelerated by aqueous phases and increased temperature.
  • Volatile compounds can be lost from samples under standard curation conditions, and mineral-volatile exchange can occur within hours to months.
  • Redox-sensitive materials and nanocrystalline/amorphous materials undergo rapid alteration upon exposure to Earth's atmosphere.
  • Time-sensitive investigations, including biological analysis and characterization of volatiles and redox-sensitive minerals, must be completed within months.

Conclusions:

  • Critical scientific information from Mars returned samples is at risk of permanent loss due to time-sensitive processes.
  • Sample Receiving Facilities (SRFs) must be equipped to perform time-sensitive analyses within months of sample arrival.
  • Further research is needed to quantify volatile exchange in diverse Martian materials and develop effective stabilization strategies.