Calibration methods for VSCs measured on AS-TD-GC-SCD
Xinguang Wang1,2, Minh Le3, Richard Stuetz3
1Water Research Centre, University of New South Wales, Sydney, 2052, Australia. xwang185@hotmail.com.
Abstract:
Volatile sulfur compounds (VSCs) are key odorous compounds from emissions of various odour sources because they are odorous and generally have very low odour threshold values. Identification and quantification of them through air server-thermal desorber-gas chromatography-sulfur chemiluminescence detector (AS-TD-GC-SCD) become more and more popular, although VSCs can be determined by other detectors. To find a valid, practical and quick calibration method is also an important step in their analytical processes. This study compared three different sample preparation and unity sampling methods using both gas standards (with 10 VSCs balanced in pure nitrogen gas) and liquid standards of 7 VSCs. For liquid standard sample preparation, two solvents (methanol and n-pentane) were tested and their calibration results were compared. The study revealed that the three calibration methods with both manual and dynamic dilution of VSC standard gases can achieve satisfactory calibration results with nice linear regression and correlation coefficient (r2). The dynamic dilution and loop sampling method is recommended because of its better reliability and time-saving processing. For calibration of VSCs with liquid standards, preparing the samples using dissolved VSCs in n-pentane and analysing them using the loop sampling method achieved best calibration results. For dimethyl trisulfide (DMTS), its calibration cannot obtain as good results as other sulfur compounds even using the best performance calibration method.
More Related Videos
08:40Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Correlation Coefficient
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Gas Chromatography: Types of Detectors-II