A systematic review of facial plastic surgery simulation training models
M A Mohd Slim1, R Hurley1, M Lechner2
1Department of ENT, Queen Elizabeth University Hospital, Glasgow, Scotland, UK.
Objectives:
The coronavirus disease 2019 pandemic has led to a need for alternative teaching methods in facial plastics. This systematic review aimed to identify facial plastics simulation models, and assess their validity and efficacy as training tools.
Methods:
Literature searches were performed. The Beckman scale was used for validity. The McGaghie Modified Translational Outcomes of Simulation-Based Mastery Learning score was used to evaluate effectiveness.
Results:
Overall, 29 studies were selected. These simulated local skin flaps (n = 9), microtia frameworks (n = 5), pinnaplasty (n = 1), facial nerve anastomosis (n = 1), oculoplastic procedures (n = 5), and endoscopic septoplasty and septorhinoplasty simulators (n = 10). Of these models, 14 were deemed to be high-fidelity, 13 low-fidelity and 2 mixed-fidelity. None of the studies published common outcome measures.
Conclusion:
Simulators in facial plastic surgical training are important. These models may have some training benefits, but most could benefit from further assessment of validity.