Related Experiment Video
Updated: Oct 9, 2025

Anterior Capsular Reconstruction with Human Dermal Allograft for Irreparable Subscapularis Tears
Published on: May 9, 2025
Combination of Surgical Techniques Restores Multidirectional Biomechanical Stability of Acromioclavicular Joint
Thomas Goodine1, Haluk Celik2, Cesar Flores-Hernandez2
1Scripps Clinic Medical Group, Scripps Health, La Jolla, California, U.S.A.
Purpose:
To measure the multiaxial stability of the acromioclavicular joint before and after transection of the acromioclavicular capsule and coracoclavicular ligaments and after sequential repair of acromioclavicular and coracoclavicular ligaments.
Methods:
Biomechanical testing was performed on fresh-frozen human cadaveric shoulders (N = 6). Translational and rotational stability in the vertical and horizontal planes was measured in intact specimens, after transecting the acromioclavicular and coracoclavicular ligaments, and after sequentially performing the following procedures: single-bundle coracoclavicular repair (CCR), modified Weaver-Dunn procedure (WD), and acromioclavicular stabilization (ACS).
Results:
Resecting the acromioclavicular and coracoclavicular significantly reduced translational stiffness in the inferior and anteroposterior directions, as well as rotational stiffness about the vertical and anteroposterior axes. All 3 surgical procedures increased inferior translational stiffness relative to the intact condition (Intact: 38 ± 9 N/mm, CCR: 54 ± 23 N/mm (P = .03), CCR+WD 52 ± 20 N/mm (P = .07), CCR ± WD+ACS 50 ± 21 N/mm (P = .17)). However, the combination of CCR, modified WD, and ACS resulted in the greatest increase in stiffness in internal rotation (Intact: 12.5 ± 7.4 cNm/deg, CCR: 1.2 ± 1.1 cNm/deg, CCR+WD 7.2 ± 3.0 N∗m/deg [P = .023], CCR+WD+ACS 11.6 ± 4.9 cNm/deg [P = .055]).
Conclusions:
The cumulative stability of CCR, WD reconstruction, and ACS appears to be additive. Our findings provide a biomechanical justification for combining all three techniques. Biomechanical studies assessing the performance of various acromioclavicular repairs and reconstructions should therefore incorporate multiaxial testing in their protocols.
Clinical Relevance:
Multiple points of fixation that provide multidirectional stability have the potential to improve clinical outcomes and reduce failure rates of acromioclavicular joint repair or stabilization.