Related Experiment Video
Updated: Oct 9, 2025

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Heparin-Induced Thrombocytopenia under Mechanical Circulatory Support by Large Impella for Acute Cardiogenic Shock
Yukiharu Sugimura1, Sebastian Bauer1, Moritz Benjamin Immohr1
1Department of Cardiac Surgery and Research Group for Experimental Surgery, Medical Faculty and University Hospital Düsseldorf, Heinrich Heine University Hospital, 40225 Düsseldorf, Germany.
Despite the critical feature of heparin-induced thrombocytopenia (HIT) for patients on mechanical circulatory support, reports on its incidence and outcome are still scarce. Thus, we report on clinical features of HIT in patients under Impella 5.0 or 5.5 (Abiomed Inc., Danvers, MA, USA) (Impella 5+) support for acute cardiogenic shock (CS) by focusing on observed thrombotic events. Between November 2018 and December 2020, a total of 56 consecutive patients were enrolled in a single-center retrospective study. A total of 21 patients (37.5%) were tested for HIT, and 6 (10.7%) proved positive for HIT at 10.5 ± 2.89 days after the first heparin administration during current admission. Interestingly, thrombocyte counts dropped under Impella support in all groups (all cases, no HIT test, and HIT negative group: p < 0.001, HIT-positive group: p = 0.001). All HIT-positive patients were switched from heparin to argatroban. HIT-associated thrombotic events were observed in two cases resulting in Impella dysfunction due to pump thrombosis (n = 1) and left ventricular (LV) thrombus formation (n = 1). Under large Impella support, the prevalence of HIT was relatively high. Further, thrombocytopenia does not deliver a high specificity in the setting of Impella 5+ support. Considering HIT manifestation, a routine HIT test may be considered to avoid critical thrombotic adverse events.
Despite the critical feature of heparin-induced thrombocytopenia (HIT) for patients on mechanical circulatory support, reports on its incidence and outcome are still scarce. Thus, we report on clinical features of HIT in patients under Impella 5.0 or 5.5 (Abiomed Inc., Danvers, MA, USA) (Impella 5+) support for acute cardiogenic shock (CS) by focusing on observed thrombotic events. Between November 2018 and December 2020, a total of 56 consecutive patients were enrolled in a single-center retrospective study. A total of 21 patients (37.5%) were tested for HIT, and 6 (10.7%) proved positive for HIT at 10.5 ± 2.89 days after the first heparin administration during current admission. Interestingly, thrombocyte counts dropped under Impella support in all groups (all cases, no HIT test, and HIT negative group: p < 0.001, HIT-positive group: p = 0.001). All HIT-positive patients were switched from heparin to argatroban. HIT-associated thrombotic events were observed in two cases resulting in Impella dysfunction due to pump thrombosis (n = 1) and left ventricular (LV) thrombus formation (n = 1). Under large Impella support, the prevalence of HIT was relatively high. Further, thrombocytopenia does not deliver a high specificity in the setting of Impella 5+ support. Considering HIT manifestation, a routine HIT test may be considered to avoid critical thrombotic adverse events.
More Related Videos
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care