Abstract:
ECG-gated multidetector computed tomography (MDCT) is a promising complementary technique for evaluation of cardiac native and prosthetic structures. MDCT is able to provide a broader coverage with faster scan acquisition times that yield higher spatial and temporal resolution for cardiac structures whose quality may be affected by artifacts on ultrasound. We report a case series about the most challenging complications occurring after prosthetic aortic valve implantation in four patients: pannus, paravalvular leak, prosthesis' misfolding and subaortic membrane reformation. In all the cases, enhanced MDCT using a retrospective protocol provided accurate 3D morphoanatomic information about cardiac and extracardiac structures, improving and speeding up the correct diagnosis and treatment planning. Integrated imaging, in particular with MDCT, is now the present, and it will increasingly be the future in the assessment of cardiac structural pathology.