Related Experiment Video
Updated: Oct 9, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Portal Vein Pulsatility as a Dynamic Marker of Venous Congestion Following Cardiac Surgery: An Interventional Study
Pierre Huette1, Pierre-Grégoire Guinot2, Guillaume Haye1
1Anesthesia and Critical Care Medicine Department, Amiens Hospital University, 80000 Amiens, France.
Abstract:
We aimed to assess variations in the portal vein pulsatility index (PI) during mechanical ventilation following cardiac surgery.
Method:
After ethical approval, we conducted a prospective monocentric study at Amiens University Hospital. Patients under mechanical ventilation following cardiac surgery were enrolled. Doppler evaluation of the portal vein (PV) was performed by transthoracic echography. The maximum velocity (VMAX) and minimum velocity (VMIN) of the PV were measured in pulsed Doppler mode. The PI was calculated using the following formula (VMAX - VMIN)/(VMax). A positive end-expiratory pressure (PEEP) incremental trial was performed from 0 to 15 cmH2O, with increments of 5 cmH2O. The PI (%) was assessed at baseline and PEEP 5, 10, and 15 cmH2O. Echocardiographic and hemodynamic parameters were recorded.
Results:
In total, 144 patients were screened from February 2018 to March 2019 and 29 were enrolled. Central venous pressure significantly increased for each PEEP increment. Stroke volumes were significantly lower after PEEP incrementation, with 52 mL (50-55) at PEEP 0 cmH2O and 30 mL (25-45) at PEEP 15 cmH2O, (p < 0.0001). The PI significantly increased with PEEP incrementation, from 9% (5-15) at PEEP 0 cmH2O to 15% (5-22) at PEEP 5 cmH2O, 34% (23-44) at PEEP 10 cmH2O, and 45% (25-49) at PEEP 15 cmH2O (p < 0.001).
Conclusion:
In the present study, PI appears to be a dynamic marker of the interaction between mechanical ventilation and right heart pressure after cardiac surgery. The PI could be a useful noninvasive tool to monitor venous congestion associated with mechanical ventilation.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Measurement of Blood Pressure
Cardiomyopathy VII: Pre and Post Operative Nursing Management