Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Liver Enhancement on Computed Tomography Is Suboptimal in Patients with Liver Steatosis
Véronique V van Cooten1, Daan J de Jong1, Frank J Wessels1
1Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
Abstract:
This study's aim was twofold. Firstly, to assess liver enhancement quantitatively and qualitatively in steatotic livers compared to non-steatotic livers on portal venous computed tomography (CT). Secondly, to determine the injection volume of contrast medium in patients with severe hepatic steatosis to improve the image quality of the portal venous phase. We retrospectively included patients with non-steatotic (n = 70), the control group, and steatotic livers (n = 35) who underwent multiphase computed tomography between March 2016 and September 2020. Liver enhancement was determined by the difference in attenuation in Hounsfield units (HU) between the pre-contrast and the portal venous phase, using region of interests during in three different segments. Liver steatosis was determined by a mean attenuation of ≤40 HU on unenhanced CT. Adequate enhancement was objectively defined as ≥50 ΔHU and subjectively using a three-point Likert scale. Enhancement of non-steatotic and steatotic livers were compared and associations between enhancement and patient- and scan characteristics were analysed. Enhancement was significantly higher among the control group (mean 51.9 ± standard deviation 11.5 HU) compared to the steatosis group (40.6 ± 8.4 HU p for difference < 0.001). Qualitative analysis indicated less adequate enhancement in the steatosis group: 65.7% of the control group was rated as good vs. 8.6% of the steatosis group. We observed a significant correlation between enhancement, and presence/absence of steatosis and grams of iodine per total body weight (TBW) (p < 0.001; adjusted R2 = 0.303). Deduced from this correlation, theoretical contrast dosing in grams of Iodine (g I) can be calculated: g I = 0.502 × TBW for non-steatotic livers and g I = 0.658 × TBW for steatotic livers. Objective and subjective enhancement during CT portal phase were significantly lower in steatotic livers compared to non-steatotic livers, which may have consequences for detectability and contrast dosing.
More Related Videos
07:12Author Spotlight: Analysis of Fluorescent-Stained Lipid Droplets with 3D Reconstruction for Hepatic Steatosis Assessment
Published on: June 2, 2023
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies III: Computed Tomography
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Gross Anatomy of the Liver
Located under the diaphragm, the liver is almost entirely ensconced within the rib cage, providing it with substantial protection. Except for the superior most bare area, the liver's surface is...