Radiation Protection in Interventional Radiology/Cardiology-Is State-of-the-Art Equipment Used?
Christiane Behr-Meenen1, Heiner von Boetticher2, Jan Felix Kersten1
1Competence Centre for Epidemiology and Health Services Research for Healthcare Professionals (CVcare), Institute for Health Services Research in Dermatology and Nursing (IVDP), University Medical Centre Hamburg-Eppendorf (UKE), 20246 Hamburg, Germany.
Abstract:
Interventional radiology/cardiology is one of the fields with the highest radiation doses for workers. For this reason, the International Commission on Radiological Protection (ICRP) published new recommendations in 2018 to shield staff from radiation. This study sets out to establish the extent to which these recommendations are observed in Germany. For the study, areas were selected which are known to have relatively high radiation exposure along with good conditions for radiological protection-interventional cardiology, radiology and vascular surgery. The study was advertised with the aid of an information flyer which was distributed via organisations including the German Cardiac Society (Deutsche Gesellschaft für Kardiologie- Herz- und Kreislaufforschung e. V.). Everyone who participated in our study received a questionnaire to record their occupational medical history, dosimetry, working practices, existing interventional installations and personal protective equipment. The results were compared with international recommendations, especially those of the ICRP, based on state-of-the-art equipment. A total of 104 respondents from eight German clinics took part in the survey. Four participants had been medically diagnosed with cataracts. None of the participants had previously worn an additional dosimeter over their apron to determine partial-body doses. The interventional installations recommended by the ICRP have not been fitted in all examination rooms and, where they have been put in place, they are not always used consistently. Just 31 participants (36.6%) stated that they "always" wore protective lead glasses or a visor. This study revealed considerable deficits in radiological protection-especially in connection with shielding measures and dosimetric practices pertaining to the head and neck-during a range of interventions. Examination rooms without the recommended interventional installations should be upgraded in the future. According to the principle of dose minimization, there is considerable potential for improving radiation protection. Temporary measurements should be taken over the apron to determine the organ-specific equivalent dose to the lens of the eye and the head.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiation: Applications
The average...
Imaging Studies for Cardiovascular System V: CT


