Beyond the wrist: Using a smartwatch electrocardiogram to detect electrocardiographic abnormalities
Related Experiment Video
Updated: Oct 8, 2025

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Sylvain Ploux1, Marc Strik1, Théo Caillol1
1Cardiothoracic unit, Bordeaux university hospital, CHU, 33600 Pessac, France; IHU Liryc, Electrophysiology and Heart Modelling Institute, Fondation Bordeaux université, 33600 Pessac, France.
Background:
When worn on the wrist, smartwatch electrocardiograms may provide important but incomplete information.
Aims:
We sought to evaluate the added benefit of placing the smartwatch on the ankle and on the chest to diagnose various electrocardiographic abnormalities compared with 12-lead electrocardiograms.
Methods:
Two hundred and sixty patients with (n=189) or without (n=71) known cardiac disorders underwent 12-lead electrocardiogram and smartwatch electrocardiogram recordings of lead I (AW-I) and of leads I and II and pseudo chest leads V1 and V6 (AW-4). AW-I and AW-4 diagnoses (three-cardiologist consensus) were compared with 12-lead electrocardiogram diagnoses (three-cardiologist consensus) to calculate sensitivity and specificity.
Results:
AW-I showed high accuracy for the diagnoses of atrial fibrillation (96% sensitivity, 91% specificity) and complete bundle branch block (85% sensitivity, 98% specificity). Compared with AW-I, AW-4 improved detection of an abnormal 12-lead electrocardiogram (91% vs. 80% sensitivity; P<0.01), atrial flutter/tachycardia (69% vs. 25% sensitivity; P=0.04), T-wave abnormalities (77% vs. 34% sensitivity; P<0.01), pathological Q-waves (41% vs. 7% sensitivity; P<0.01) and left anterior hemiblock (70% vs. 0% sensitivity; P=0.02). AW-4 also enabled better differentiation between atrioventricular block and sinus bradycardia (from 81% to 95% correct; P=0.03) and between atrial fibrillation and atrial flutter/tachycardia (from 71% to 89% correct; P=0.02), but not between bundle branch blocks (from 82% to 87% correct; P=0.57).
Conclusions:
A smartwatch electrocardiogram on the wrist accurately diagnoses atrial fibrillation and bundle branch block. Recording additional leads significantly improves the accuracy of detecting an abnormal electrocardiogram and repolarization changes, and also allows for better differentiation of brady- and tachyarrhythmias.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Holter Monitor: 24-Hour Monitoring
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....