Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
3.7K
Five-Year Outcomes of Concomitant Maze Procedure Using Nitrous Oxide vs Argon-Based Cryoablation
Ilkun Park1, Dong Seop Jeong2, Joong Hyun Ahn2
1Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
The Annals of Thoracic Surgery
|December 26, 2021
Summary
Nitrous oxide (N2O) and argon cryoprobes demonstrated comparable long-term efficacy and safety for myocardial ablation. Both methods effectively maintained sinus rhythm and freedom from major adverse cardiovascular and cerebrovascular events over five years.
Area of Science:
- Cardiology
- Medical Devices
- Electrophysiology
Background:
- Cryoablation is a recognized method for myocardial ablation, preserving tissue structure.
- Limited comparative data exists for nitrous oxide (N2O)-based versus argon gas-based cryoprobes.
Purpose of the Study:
- To compare the long-term efficacy and safety of N2O-based and argon gas-based cryoprobes for myocardial ablation.
- To evaluate sinus rhythm maintenance and major adverse cardiovascular and cerebrovascular events (MACCEs) at 5-year follow-up.
Main Methods:
- A follow-up of a single-center, prospective, randomized controlled trial involving 60 patients.
- Patients were randomized into N2O or argon cryoprobe groups.
- Primary endpoint: sinus rhythm maintenance; Secondary endpoint: MACCEs (cardiac death, stroke, major bleeding, heart failure readmission).
Main Results:
- Comparable baseline and operative characteristics between N2O and argon groups.
- At 5-year follow-up, sinus rhythm maintenance was 81.8% (N2O) vs. 78.5% (argon) (P > .999).
- No significant difference in freedom from MACCEs (80.6% N2O vs. 81.9% argon; P = .978); significant reduction in left atrial volume index in both groups.
Conclusions:
- Both N2O and argon cryoprobes exhibit similar long-term efficacy in maintaining sinus rhythm.
- Comparable safety profiles were observed, with similar rates of MACCEs at 5-year follow-up.
- N2O and argon cryoprobes may offer similar efficacy and safety for arrested heart procedures long-term.