Related Experiment Video
Updated: Oct 8, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Multispectral Mid-Infrared Camera System for Accurate Stand-Off Temperature and Column Density Measurements on Flames
Juan Meléndez1, Guillermo Guarnizo1
1LIR-Infrared Laboratory, Department of Physics, Universidad Carlos III de Madrid, 28911 Leganés, Spain.
Abstract:
Accurate measurement of temperature in flames is a challenging problem that has been successfully addressed by hyperspectral imaging. This technique is able to provide maps of not only temperature T (K) but also of column density Q (ppm·m) of the main chemical species. Industrial applications, however, require cheaper instrumentation and faster and simpler data analysis. In this work, the feasibility and performance of multispectral imaging for the retrieval of T and QCO2 in flames are studied. Both the hyperspectral and multispectral measurement methods are described and applied to a standard flame, with known T and QCO2, and to an ordinary Bunsen flame. Hyperspectral results, based on emission spectra with 0.5 cm-1 resolution, were found in previous works to be highly accurate, and are thus considered as the ground truth to compare with multispectral measurements of a mid-IR camera (3 to 5 μm) with a six interference filter wheel. Maps of T and Q obtained by both methods show that, for regions with T ≳1300 K, the average of relative errors in multispectral measurements is ∼5% for T (and can be reduced to ∼2.5% with a correction based on a linear regression) and ∼20% for Q. Results obtained with four filters are very similar; results with two filters are also similar for T but worse for Q.
More Related Videos
10:29Experimental Methodology for Estimation of Local Heat Fluxes and Burning Rates in Steady Laminar Boundary Layer Diffusion Flames
Published on: June 1, 2016
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Flame Photometry: Overview
Flame Photometry: Lab
IR Spectrometers
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...