Related Experiment Video
Updated: Oct 8, 2025

04:01
The Modified Single-working Portal Technique Using Lasso-loop Stitch with Needle for Arthroscopic Subscapularis Repair
Published on: August 8, 2025
91
Lasso loop technique using bioabsorbable thread to treat intra-articular distal radius fracture
Yoshio Kaji1, Konosuke Yamaguchi1, Yumi Nomura1
1Department of Orthopaedic Surgery, Kagawa University Faculty of Medicine, Ikenobe, Miki-cho, Kita-gun, Kagawa, Japan.
Medicine
|December 29, 2021
Summary
The novel lasso loop technique (LLT) effectively treats distal radius fractures with displaced bone fragments, significantly reducing the articular gap. This minimally invasive approach shows promising results with minimal complications.
Area of Science:
- Orthopedic surgery
- Biomaterials engineering
Background:
- Intra-articular distal radius fractures with displaced dorsal bone fragments (DBF) pose treatment challenges.
- Maintaining articular congruity is crucial for optimal functional outcomes.
Purpose of the Study:
- To introduce and evaluate the efficacy of the lasso loop technique (LLT) using a bioabsorbable thread for treating intra-articular distal radius fractures with DBF.
- To assess the reduction and maintenance of the articular gap, radiological parameters, and clinical outcomes following LLT.
Main Methods:
- Retrospective review of 19 patients who underwent LLT for intra-articular distal radius fractures with DBF.
- Analysis of radiographic images (CT and plain radiographs) and clinical data, including the Quick Disabilities of the Arm, Shoulder, and Hand (QDASH) scores.
Main Results:
- LLT significantly reduced the mean preoperative articular gap (2.6 mm) to <1.0 mm immediately postoperatively.
- No re-displacement of DBF was observed up to 6 months postoperatively.
- Satisfactory maintenance of palmar tilt, radial inclination, ulnar variance, joint range of motion, grip strength, and QDASH scores were achieved with no significant complications.
Conclusions:
- The lasso loop technique (LLT) provides a simple, effective, and safe method for reducing displaced dorsal bone fragments in intra-articular distal radius fractures.
- LLT demonstrates potential as a valuable treatment option for this specific fracture pattern, promoting good functional recovery.