Related Experiment Video
Updated: Oct 8, 2025

Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
A Strategy for Simultaneously Improving Resolution and Sensitivity of Hybrid Quadrupole Ion Trap/Time-of-Flight Mass
Yixue Cao1,2,3, Ping Chen1,3, Lei Hua1,3
1CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
Abstract:
The hybrid quadrupole ion trap/time-of-flight mass spectrometry (QIT/TOFMS) device is popular because of its advantages of high sensitivity, high resolution, and MS/MS capability. However, the analytical performance of QIT/TOFMS is severely limited by the parameters of the ion trap, as QIT is typically used as a TOF pulser because the ion initial distributions of space, velocity, and angle change dynamically with the phase angle of rf voltage. In this work, a square waveform phase modulation strategy was proposed to eliminate the influence of the rf phase angle, and the dependence of QIT/TOFMS performance on the phase angle was studied. It was found that the mass resolution and signal intensity showed a "W" trend with the increase of the ion extraction phase angle from 0° to 360°, where the best resolution and sensitivity were obtained at 0°, 180°, and 360° while the worst resolution and sensitivity were obtained at 90° and 270°. Moreover, the optimum phase angle was independent of m/z. As a result, the mass resolution for m/z 106, 164, and 258 was improved by 162%, 160%, and 210% respectively, while the signal intensities for m/z 106, 164, and 258 were enhanced by 25 ± 1, 10 ± 1, and 21 ± 1 fold, respectively, and a limit of detection down to 0.015 ppbv for m/z 164 was obtained. The experiment results indicated that the square waveform phase modulation strategy could be used to simultaneously improve the resolution and sensitivity of QIT/TOFMS.
Related Concept Videos
Mass Analyzers: Common Types
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Analyzers: Overview
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)

