Analysis of short-chain bioactive peptides by unified chromatography-electrospray ionization mass spectrometry. Part
Jérémy Molineau1, Maria Hideux2, Philippe Hennig2
1University of Orleans, ICOA, CNRS UMR 7311, rue de Chartres, BP 6759; 45067 Orléans, France.
Abstract:
In the first part of this study, a unified chromatography (UC) analysis method, which is similar to supercritical fluid chromatography (SFC) but with wide mobile phase gradients of pressurized CO2 and solvent, was developed to analyse short-chain peptides, with UV and mass spectrometry (MS) detection. In this second part, the method is compared to a reference reversed-phase ultra-high-performance liquid chromatography (RP-UHPLC) method, based on the analysis of 43 peptides, including 10 linear peptides and 33 cyclic ones. First, the orthogonality between the two methods was examined, based on the retention patterns. As the UC method was developed on a polar stationary phase (Ascentis Express OH5), the elution orders and selectivities were expected to be significantly different from RPLC on a non-polar stationary phase (ACQUITY CSH C18). Secondly, the success rate of the methods was examined, based on successful retention / elution of the peptides and the absence of observed co-elutions between the main peak and impurities. A successful analysis was obtained for 81% of the peptides in UC and 67% in RPLC. Thirdly, the performance of the methods for the intended application of impurity profiling of peptide drug candidates was assessed, based on the comparison of peak purities, the number of impurities detected and the thorough examination of impurity profiles. Excellent complementarity of the two methods for the specific task of impurity profiling, and for the separation of isomeric species was observed, with only one isomeric pair in this set remaining unresolved. The method sensitivity was however better with RPLC than UC. Finally, the operational costs in terms of solvent cost per analysis were the same between the two methods.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Ion-Exchange Chromatography
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...