Related Experiment Video
Updated: Oct 8, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
The Effectiveness of Capnography Versus Pulse Oximetry in Detecting Respiratory Adverse Events in the Postanesthesia
Margaret M McNeill1, Connie Hardy Tabet2
1Nursing Professional Development, Frederick Health Hospital, Frederick, MD.
Purpose:
The objective of this review was to evaluate the effectiveness of capnography monitoring versus standard monitoring of pulse oximetry in detecting respiratory adverse events in nonintubated pediatric and adult postanesthesia care unit (PACU) patients.
Design:
Experimental, quasi-experimental, and observational studies examining pulse oximetry and capnography in adult and pediatric patients in the PACU were included in this systematic review.
Methods:
An initial search of MEDLINE and CINAHL, PubMed, Web of Science, Prospero, Google Scholar, and Cochrane was undertaken to identify articles on the topic. The text words contained in the titles and abstracts of relevant articles, and the index terms used to describe the articles were used to develop a full search strategy in July 2019. Reference lists of studies included at critical appraisal stage were hand-searched. Studies published in English from 1978 onward were included.
Findings:
Meta-analysis was not possible due to variation in outcome measurements; therefore, results are presented in narrative form. Four studies were included in the review: 1 randomized controlled trial (RCT) and 3 observational cross-sectional studies. The RCT was considered of moderate to high quality, and the observational cross-sectional studies were of high quality. The main findings of this review suggest that there is limited high-quality evidence that capnography improves detection of respiratory adverse events in the PACU versus pulse oximetry.
Conclusions:
The lack of RCTs and varied outcomes measures in the 4 studies reviewed meant that meta-analysis was not possible. Early detection of respiratory adverse events afforded by the addition of PETCO2 to SpO2 in the PACU was seen in these studies. More research is needed to determine if widespread implementation of capnography in addition to pulse oximetry would reduce severity of respiratory related adverse events in the PACU through more timely identification.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Acute Respiratory Failure-III