Related Experiment Video
Updated: Oct 8, 2025

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
Infrared Thermography Images Acquisition for a Technical Perspective in Screening and Diagnostic Processes: Protocol
Stefano Politi1, Anna Aloisi1, Vittorio Bartoli1
1Aerospace Medicine, Diagnostic Therapeutic and Rehabilitative Aeromedical Center, Italian Air Force, Rome, ITA.
Abstract:
In this technical report we describe the thermographic setting protocol suitable for the FLIR T650SC thermal imager (FLIR Systems, Inc., Wilsonville, OR), an instrument that detects electromagnetic radiation in the infrared field which is physiologically emitted from the human body. FLIR T650SC thermal imager processes infrared radiations graphically and analyzes them through a specific software. In biomedicine, infrared thermography is a promising technique amongst other conventional methods used for detecting skin temperature differences considered as a possible sign of disturbances in the human body. Currently, automatic screening of temperature from a safe distance is an instrument utilized in the front line of the SARS CoV2 emergency. The processing method of the thermogram considers an initial setting of constant parameters that cannot be subsequently modified such as temperature range, focusing and image composition. After the acquisition variable values important in the processing and analysis of the thermogram, such as detection of environment temperature, reflected temperature, emissivity, relative humidity and contrast palette, are set in the software. The analysis is performed using the FLIR Tools software. In the biomedical field standardized acquisition of thermograms facilitates the identification of trigger points and areas of hyper- and hypothermia distributed on the skin surface and muscle bundles. The protocol made it possible to create images with the same acquisition method for all patients. The thermal imaging camera is a valid screening tool because its execution is rapid, it is non-invasive, well-tolerated, and at a low cost for patients.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
IR Spectrometers
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...