New Method to Estimate Central Systolic Blood Pressure From Peripheral Pressure: A Proof of Concept and Validation
Denis Chemla1,2,3, Sandrine Millasseau4, Olfa Hamzaoui5
1Service d'explorations fonctionnelles multidisciplinaires bi-site Antoine Béclère - Kremlin Bicêtre, GHU Paris Sud, AP-HP, Le Kremlin-Bicêtre, France.
Abstract:
Objective: The non-invasive estimation of central systolic blood pressure (cSBP) is increasingly performed using new devices based on various pulse acquisition techniques and mathematical analyses. These devices are most often calibrated assuming that mean (MBP) and diastolic (DBP) BP are essentially unchanged when pressure wave travels from aorta to peripheral artery, an assumption which is evidence-based. We tested a new empirical formula for the direct central blood pressure estimation of cSBP using MBP and DBP only (DCBP = MBP2/DBP). Methods and Results: First, we performed a post-hoc analysis of our prospective invasive high-fidelity aortic pressure database (n = 139, age 49 ± 12 years, 78% men). The cSBP was 146.0 ± 31.1 mmHg. The error between aortic DCBP and cSBP was -0.9 ± 7.4 mmHg, and there was no bias across the cSBP range (82.5-204.0 mmHg). Second, we analyzed 64 patients from two studies of the literature in whom invasive high-fidelity pressures were simultaneously obtained in the aorta and brachial artery. The weighed mean error between brachial DCBP and cSBP was 1.1 mmHg. Finally, 30 intensive care unit patients equipped with fluid-filled catheter in the radial artery were prospectively studied. The cSBP (115.7 ± 18.2 mmHg) was estimated by carotid tonometry. The error between radial DCBP and cSBP was -0.4 ± 5.8 mmHg, and there was no bias across the range. Conclusion: Our study shows that cSBP could be reliably estimated from MBP and DBP only, provided BP measurement errors are minimized. DCBP may have implications for assessing cardiovascular risk associated with cSBP on large BP databases, a point that deserves further studies.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: