The assessment of temperature amplitude arising during the implant bed formation in relation to variable preparation
Piotr Kosior1, Anna Nikodem2, Marta Kozuń2
1Department of Conservative Dentistry with Endodontics, Wroclaw Medical University, Wrocław, Poland.
Abstract:
The main purpose of this study was to analyse the temperatures generated during the bone bed preparation, given the internal structure of the bone bed, the geometry of the hole, and the treatment parameters such as the type of cooling and the rotational speed of the drill. The investigated material was domestic pig ribs, in which holes were drilled three times using two drill bit systems used for Hiossen® and Paltop® dental implantation. The ThermaCAM® P640 thermal imaging camera was used for measurement of drilling temperatures. After the holes were drilled, each rib was examined using the 1172 SkyScan microtomograph, Bruker®, to compare the geometry of the machined holes. The presented study proved that larger diameter drill bits (Hiossen® drill bits) generate more heat during the machining process, as evidenced by higher temperatures obtained for the Hiossen system in each case. It was proved that rotational speed, drill bit diameter and cooling system have a significant effect on the amount of heat generated during bone tissue preparation. The density and type of bone tissue in which the hole is prepared are significant factors affecting the amount of heat generated.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...