Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

717
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
717
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

570
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
570
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

309
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
309
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

1.2K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
1.2K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

901
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
901
Flame Photometry: Lab01:16

Flame Photometry: Lab

440
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
440

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Spatial Phase Coherence in Femtosecond Coherent Raman Scattering.

Physical review letters·2026
Same author

Spatial characterization of sideways lasing.

Optics express·2025
Same author

Light-field amplitude control for multi-photon fluorescence imaging.

Optics express·2025
Same author

Interferometric quantum control (IQC) by fs/ns rotational coherent anti-Stokes Raman spectroscopy (RCARS).

Optics express·2023
Same author

Spatial monitoring of flying insects over a Swedish lake using a continuous-wave lidar system.

Royal Society open science·2023
Same author

Simultaneous single-shot imaging of H and O atoms in premixed turbulent flames using femtosecond two-photon laser-induced fluorescence.

Optics express·2023

Related Experiment Video

Updated: Oct 8, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.3K

Quantitative Hydrogen Chloride Detection in Combustion Environments Using Tunable Diode Laser Absorption Spectroscopy

Wubin Weng1, Jim Larsson1, Joakim Bood1

  • 1Division of Combustion Physics, 5193Lund University, Lund, Sweden.

Applied Spectroscopy
|January 4, 2022
PubMed
Summary

Accurate hydrogen chloride (HCl) monitoring in combustion is crucial. This study developed an improved Infrared Tunable Diode Laser Absorption Spectroscopy (IR-TDLAS) method by obtaining new water vapor spectra, enabling precise HCl measurements and temperature derivation.

Keywords:
Hydrogen chlorideTDLASbiomasscombustion–gasification environmentshigh temperaturehot water linetunable diode laser absorption spectroscopywaste

More Related Videos

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
09:40

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown

Published on: February 14, 2014

14.4K
Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

639

Related Experiment Videos

Last Updated: Oct 8, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.3K
Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
09:40

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown

Published on: February 14, 2014

14.4K
Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

639

Area of Science:

  • Combustion diagnostics
  • Spectroscopy
  • Environmental monitoring

Background:

  • Hydrogen chloride (HCl) monitoring is vital for efficient combustion/gasification of biomass and waste.
  • Infrared Tunable Diode Laser Absorption Spectroscopy (IR-TDLAS) is a suitable in-situ method for harsh environments.
  • Water vapor interference in IR-TDLAS can lead to significant HCl overestimation.

Purpose of the Study:

  • To develop accurate HCl measurement techniques for combustion environments.
  • To address spectral interference from water vapor in IR-TDLAS.
  • To obtain precise temperature-dependent water spectra for improved accuracy.

Main Methods:

  • Utilized IR-TDLAS targeting the R(3) line of HCl's ν2 band (5739.25 cm⁻¹).
  • Experimentally determined accurate temperature-dependent water spectra in hot flue gas (1100–1950 K).
  • Applied the improved method to measure HCl release and temperature over burning PVC particles.

Main Results:

  • Established accurate temperature-dependent water spectra near 5739.3 cm⁻¹.
  • Achieved an HCl detection limit of approximately 100 ppm·m at 1500 K.
  • Successfully measured temporally resolved HCl release and local temperature at 1790 K.

Conclusions:

  • Accurate water spectra are essential for precise HCl monitoring using IR-TDLAS.
  • The developed IR-TDLAS system enables simultaneous HCl measurement and temperature derivation.
  • This technique is effective for real-time monitoring of combustion processes involving HCl.