A conceptual model for changes in finger photoplethysmograph signals caused by hand posture and isothermic regulation
C Keogh1, G B Drummond1, A Bates1
1Departments of Anaesthesia, Critical Care and Pain Medicine, and Centre for Speckled Computing, School of Informatics, University of Edinburgh, United Kingdom.
Abstract:
Objective. To observe changes in baseline position and pulsatile light absorbance (photoplethysmograph, PPG) in the finger-tip, by raising the hand above the horizontal plane in recumbent subjects. We applied current knowledge of the circulation to the finger-tip, particularly arteriovenous anastomoses (AVAs), and the physiology of the venous circulation.Approach.We studied healthy young volunteers in a quiet thermoneutral environment. A finger plethysmograph on the non-dominant hand recorded transmission of red and infra-red light, with observations expressed as absorbance to allow comparisons within and between subjects. Breathing movements were recorded unobtrusively to assess any effect on absorbance and the pulse amplitude of the signals. All body movements were passive: the study arm was elevated in a trough to about 40° above the horizontal plane. The following conditions were studied, each for 15 min, using the last 10 min for analysis: recumbent, study arm elevated, study arm horizontal, and both legs elevated by 40°.Main results. We found a substantial time-related effect, and considerable variation between subjects. Arm elevation reduced red light absorbance and increased the range of amplitudes of the PPG waveform: only in subjects with large absorbances, did waveform amplitude increase. Spontaneous, thermoregulatory decreases in absorbance were large and associated with decreases in waveform amplitude.Significance. Finger-tip vessels distend with blood and light absorbance increases when AVAs open. The vessels pulsate more strongly when the hand is raised: venous collapse allows the vessels to become more compliant. The postcapillary circulation is likely to be an important source of pulsation.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Body Temperature
Thermoregulation
Thermosensation