Knowledge-based planning using pseudo-structures for volumetric modulated arc therapy (VMAT) of postoperative uterine
Tatsuya Kamima1, Yoshihiro Ueda2, Jun-Ichi Fukunaga3
1Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo, Japan.
Background:
The aim of this study was to investigate the performance of the RapidPlan (RP ) using models registered pseudostructures, and to determine how many structures are required for automatic optimization of volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer.
Materials And Methods:
Pseudo-structures around the PTV were retrospectively contoured for patients who had completed treatment at five institutions. For 22 common patients, plans were generated with a single optimization for models with two (RP_2), four (RP_4), and five (RP_5) registered structures, and the dosimetric parameters of these models were compared with a clinical plan with several optimizations.
Results:
Most dosimetric parameters showed no major differences between each RP model. In particular, the rectum Dmax, V50Gy, and V40Gy with RP_2, RP_4, and RP_5 were not significantly different, and were lower than those of the clinical plan. The average proportions of plans achieving acceptable criteria for dosimetric parameters were close to 100% for all models. Using RP_2, the average time for the VMAT planning was reduced by 88 minutes compared with the clinical plan.
Conclusion:
The RapidPlan model with two registered pseudo-structures could generate clinically acceptable plans while saving time.