Related Experiment Video
Updated: Jul 21, 2026

Using a Real-Time Locating System to Measure Walking Activity Associated with Wandering Behaviors Among Institutionalized Older Adults
Published on: February 8, 2019
Real-time tracking of a moving target in an indoor corridor of the hospital building using RSSI signals received from
Apidet Booranawong1, Peeradon Thammachote2, Yoschanin Sasiwat2
1Department of Electrical Engineering, Faculty of Engineering, Prince of Songkla University, Songkhla, 90110, Thailand. apidet.boo@gmail.com.
Abstract:
In this paper, implementation and validation of a target tracking system based on the received signal strength indicator (RSSI) for an indoor corridor environment of the hospital is presented. Six tracking methods of a moving target (i.e., equipment, robot, or human) using RSSI signals measured from two stationary reference nodes located at the different sides of the corridor are proposed. A filter with its optimal weight value is also applied to smoothen and increase the accuracy of estimated position results (i.e., the x-position in the corridor). Additionally, a determination approach for finding the optimal parameters assigned for the proposed tracking methods and the filter are also introduced. The proposed methods are implemented in MATLAB/Simulink, and experiments using a 2.4 GHz, IEEE 802.15.4/ZigBee wireless network have been carried out in the indoor corridor of the hospital building. Experimental results obtained from the corridor size of 22 m demonstrate that our proposed methods can automatically and efficiently track the moving target in real time. The average distance errors, in the case of varying and manual tuning the optimal parameters of the proposed methods and the filter, reduce from 5.14 to 1.01 m and 4.55 to 0.86 m (i.e., two test cases; slow moving speed and double moving speed). Here, the errors decrease by 80.35% and 81.10%, respectively. For the case using the optimal parameters determined by the optimization approach, the average errors can reduce to 0.97 m for the first test case and 0.78 m for the second test case, respectively. An RSSI-based real-time tracking system for a moving target in an indoor corridor of the hospital building.
More Related Videos
08:32Tracking Rats in Operant Conditioning Chambers Using a Versatile Homemade Video Camera and DeepLabCut
Published on: June 15, 2020
10:25Technical Approach for Infrared Tracking for Soft Tissue Navigation with a Holographic Head-Mounted Display and Preclinical Validation
Published on: September 2, 2025
Related Concept Videos
Hospitals-II
Nurses that work in hospitals have...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Distance Measurements by Taping
Real-World Applications of Space Curves