Related Experiment Video
Updated: Oct 7, 2025

Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Mixed-acidic cation-exchange material for the separation of underivatized amino acids
Matthias Schmitt1, Marina Egorycheva1, Andreas Seubert1
1Faculty of Chemistry, Analytical Chemistry, University of Marburg, Hans-Meerwein-Str. 4, 35043 Marburg, Germany.
Abstract:
Mixed-acidic cation-exchange (MCX) columns with both strongly (SCX) and weakly (WCX) acidic functional groups were developed for the separation of standard amino acids. The resins were prepared by carboxylation of highly crosslinked monodisperse poly(styrene-divinylbenzene) copolymer particles with performic acid and subsequent sulfonation with sulfuric acid. The degree of functionalization was varied independently for each processing step and controlled by measuring pH dependent retention of the obtained resins. A series of mixed-acidic resins with different SCX/WCX-ratios was chromatographically characterized by variation of formic acid and acetonitrile concentration in the aqueous eluent. The overall cation-exchange capacity was varied from 33 to 68 µmol/mL. The comparison with two commercial columns (Metrohm Metrosep C6, WCX and Hamilton PRP X-200, SCX) revealed the additive character of the different functional group properties within MCX columns and a unique selectivity which can be adjusted by both eluent composition and SCX/WCX-ratio of the resin. The retention window between neutral and basic amino acids was altered by varying the amount of sulfonic acid groups attached to the polymer. Orthogonality plots demonstrated constant selectivity for neutral amino acids. Correlating the retention data with log P data demonstrated the influence of non-ionic hydrophobic and π-π-interactions for the separation of amino acids on PS/DVB-based cation-exchangers. An isocratic IC-ESI-MS method was developed to separate and quantitate 20 underivatized standard amino acids within 30 min. Limits of detection were between 4 and 64 nmol L-1 and a high linearity of calibration curves was obtained for all analytes. The method was validated by comparing a certified reference standard with external calibration data.
Related Concept Videos
Ion Exchange
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Affinity Chromatography
Extraction: Advanced Methods
EDTA: Auxiliary Complexing Reagents
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...