Related Experiment Video
Updated: Oct 7, 2025

Saline Lavage for Sampling of the Canine Nasal Immune Microenvironment
Published on: December 27, 2024
Development of an apparatus and procedure for evaluating the efficiency of nasal irrigation
Dawei Wu1, Feifan Chang2, Junsheng Hong3
1Department of Otolaryngology, Beijing Anzhen Hospital, Capital Medical University, Anzhen Road 2, Chaoyang District, Beijing, 100029, People's Republic of China. davidwuorl@163.com.
Background:
Although different methods of nasal irrigation have been utilized, irrigation efficiency in nasal cavities has not been well assessed. The objective of this study was to develop an apparatus and procedure for evaluating the irrigation efficiency and to explore the optimal head position during irrigation.
Methods:
Casts of the left sinonasal cavity from a healthy volunteer were made from high-resolution-computed tomography data using 3D printing with composite materials. An adjustable apparatus that allowed cast fixation at the different head positions was built. The yogurt was used to simulate mucus. The cast with 5 ml yogurt filled around the superior, middle, and inferior turbinate was fixed in six head positions including head tilt 10°, 45°, and 60° forward with or without leaning 30° to the right. The cast was irrigated with 120 ml, 175 ml, and 240 ml dyed water and was video recorded. The irrigation efficiency was calculated based on the weight difference of the cast before and after the irrigation.
Results:
Most residual yogurt was located around the superior meatus after the irrigation under different volumes and head positions. The irrigation efficiency of the rinse bottle or the pulsatile device was volume dependent, with the highest irrigation efficiency under 240 ml water. When the left sinonasal cavity was irrigated, the head position of tilt 45° forward with leaning 30° to the right was the optimal head position for these two devices when compared to other positions. The pulsatile device with 240 ml water performed better than the rinse bottle with 240 ml water regarding the irrigation efficiency under the optimal head position (0.8700 ± 0.0138 vs 0.7536 ± 0.0099, p = 0.003).
Conclusions:
The developed apparatus provided a potential method for evaluating the irrigation efficiency. The head position of tilt 45° forward with leaning 30° was suitable for patients to perform the nasal irrigation.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...