Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Published on: February 23, 2017
Curvature Detection with an Optoelectronic Measurement System Using a Self-Made Calibration Profile
Christoph Thorwartl1, Thomas Stöggl1,2, Wolfgang Teufl1
1Department of Sport and Exercise Science, University of Salzburg, Schlossallee 49, 5400 Rif, Austria.
Abstract:
So far, no studies of material deformations (e.g., bending of sports equipment) have been performed to measure the curvature (w″) using an optoelectronic measurement system OMS. To test the accuracy of the w″ measurement with an OMS (Qualisys), a calibration profile which allowed to: (i) differentiates between three w″ (0.13˙ m-1, 0.2 m-1, and 0.4 m-1) and (ii) to explore the influence of the chosen infrared marker distances (50 mm, 110 mm, and 170 mm) was used. The profile was moved three-dimensional at three different mean velocities (vzero = 0 ms-1, vslow = 0.2 ms-1, vfast = 0.4 ms-1) by an industrial robot. For the accuracy assessment, the average difference between the known w″ of the calibration profile and the detected w″ from the OMS system, the associated standard deviation (SD) and the measuring point with the largest difference compared to the defined w″ (=maximum error) were calculated. It was demonstrated that no valid w″ can be measured at marker distances of 50 mm and only to a limited extent at 110 mm. For the 170 mm marker distance, the average difference (±SD) between defined and detected w″ was less than 1.1 ± 0.1 mm-1 in the static and not greater than -3.8 ± 13.1 mm-1 in the dynamic situations. The maximum error in the static situation was small (4.0 mm-1), while in the dynamic situations there were single interfering peaks causing the maximum error to be larger (-30.2 mm-1 at a known w″ of 0.4 m-1). However, the Qualisys system measures sufficiently accurately to detect curvatures up to 0.13˙ m-1 at a marker distance of 170 mm, but signal fluctuations due to marker overlapping can occur depending on the direction of movement of the robot arm, which have to be taken into account.
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Field Procedure for Staking Out Curves
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...