Reduction of Coil-Crack Angle Sensitivity Effect Using a Novel Flux Feature of ACFM Technique

Ruochen Huang1, Mingyang Lu1, Ziqi Chen1

  • 1School of Electrical and Electronic Engineering, University of Manchester, Manchester M13 9PL, UK.

Related Concept Videos

Calculation of Electric Flux01:25

Calculation of Electric Flux

Consider the electric field of an oppositely charged, parallel-plate system and an imaginary box between those plates. Let the bottom face of the box be ABCD, and the top face be FGHK. The electric field between the plates is uniform and points from the positive plate toward the negative plate. The calculation of this field's flux through the box's various faces shows that the net flux through the box is zero. Why does the flux cancel out here?
2.3K
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
341
Mesh Analysis for AC Circuits01:12

Mesh Analysis for AC Circuits

In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
447
Source Transformation for AC Circuits01:11

Source Transformation for AC Circuits

The process of source transformation in the frequency domain entails the conversion of a voltage source, positioned in series with an impedance, into a current source that is parallel to an impedance, or the other way around. It is essential to maintain the following relationships while transitioning from one source type to another.
747
Magnetic Flux01:18

Magnetic Flux

The magnetic flux measures the number of magnetic field lines passing through a given surface area. The SI unit for magnetic flux is the weber (Wb). Magnetic flux is a scalar quantity. It depends on three factors: the strength of the magnetic field B, the area through which the field lines pass, and the relative orientation of the field with the surface area.
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
3.8K
Inductor in an AC Circuit01:16

Inductor in an AC Circuit

The basic components of an inductor are coils or loops of wire that are either wound around a hollow tube former or a ferromagnetic material (iron-cored) to increase their inductive value or inductance. When a voltage is applied across an inductor's terminals, a magnetic field is created, where the inductor stores its energy. The inductor's own self-induced or back emf value controls the growth of the current flowing through it.  This back emf voltage is proportional to the rate of...
2.5K