Constrained optimization towards marker-based tumor tracking in VMAT
Azeez Omotayo1,2, Sankar Venkataraman1,2,3, Boyd McCurdy1,2,3
1CancerCare Manitoba, Division of Medical Physics, 675 McDermot Avenue, Winnipeg, MB R3E 0V9, Canada.
Abstract:
This study proposes that incorporating marker-based visibility constraints into the optimization of volumetric modulated arc therapy (VMAT) will generate treatment plans which not only ensure a higher chance of successfully applying real-time tumor tracking techniques, but also simultaneously satisfy dosimetric objectives. This was applied clinically and investigated for multiple disease sites (10 prostate, 5 liver, and 5 lung) using a radiotherapy optimization software (MonArc), where these new constraints were added to conventional dosimetric constraints. For all the investigated sites, three fiducial markers were located inside or around the planning target volume (PTV), and VMAT plans were created for each patient. We modifiedMonArcto analyze the multi-leaf collimator (MLC) beam's-eye-view at all control points in the gantry arc, while including marker-based visibility constraints of type 'hard' (i.e. requiring 100% visibility of all markers, HC) and 'soft' (i.e. penalizes visibility for one marker [SCI] or two markers [SCII] only) in the optimization process. Dose distributions resulting from the constrained plans (HC, SCI, and SCII) were compared to the non-constrained plan (NC-plans optimized without visibility constraints) using several quantitative dose metrics including the conformity index, homogeneity index, doses to PTV and to organs-at-risk (OAR). Generally, the NC plan produced the best PTV dose conformity and the least OAR doses for the entire patient datasets, followed by the SC and then HC plans, with all the optimization approaches typically achieving acceptable dose metrics. Across the three disease sites, visibility of all three markers in MLC apertures increased from 32% to 100% of available control points as visibility constraints strengthened. Although dose metrics showed some deterioration for constrained plans (-6% for SCIup to -15% for HC using the PTV average index), the required dosimetric objectives were still satisfied in at least 90% of patients. In conclusion, we demonstrated that marker and tumour visibility constraints can be incorporated with dosimetric objectives to produce treatment plans satisfying both objectives, which should ensure greater success when applying real-time tracking for VMAT delivery.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022