Related Experiment Video
Updated: Aug 11, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
[Exercise 13NH3-positron emission computed tomography (PET) versus exercise single photon emission computed
1Department of Internal Medicine, Faculty of Medicine, Kyoto University Hospital.
Abstract:
The value of exercise positron emission computed tomography (PET) was determined by comparing it with exercise T1-201 single photon emission computed tomography (SPECT) using graded ergometer exercise in 10 anginal patients with left anterior descending coronary (LAD) involvement (stenosis greater than or equal to 75%) with or without other coronary stenosis. The distribution of N-13 ammonia or T1-201 was determined and expressed as percent count ot the highest count on the circumferential profile curve (CPC) in the transaxial image. Two standard deviations below the mean counts of six normal hearts for PET and ten for SPECT were considered as the lower limit of normal, and these were determined separately during exercise and at rest. The ischemic areas per total myocardial areas (%C), the accuracy in diagnosing coronary involvement and the identification of coronary branch involvement were determined by CPC analysis in three corresponding slices. Regional analyses revealed that accuracy in diagnosing proximal left anterior descending artery (LAD) involvement was higher with PET (9/10) than with SPECT (7/10), but the difference was not statistically significant. The accuracy in diagnosing right coronary or circumflex artery stenosis was 9/10 with PET and 8/10 with SPECT (NS); the %C was significantly higher with PET than with SPECT during exercise (PET: mean +/- SD = 56 +/- 21%, SPECT: 35 +/- 21%, p less than .01) in spite of smaller double products (x10(3] (PET: 18.9 +/- 4.7, SPECT: 23.5 +/- 5.7, p less than .02). Thus, exercise PET was more reliable in evaluating regional ischemia and in semiquantifying the ischemic area in the myocardium.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET