Objectives:
To propose and evaluate a set of radiomic features, called morphological dynamics features, for pulmonary nodule detection, which were rooted in the dynamic patterns of morphological variation and needless precise lesion segmentation.
Materials And Methods:
Two datasets were involved, namely, university hospital (UH) and LIDC datasets, comprising 72 CT scans (360 nodules) and 888 CT scans (2230 nodules), respectively. Each nodule was annotated by multiple radiologists. Denoted the category of nodules identified by at least k radiologists as ALk. A nodule detection algorithm, called CAD-MD algorithm, was proposed based on the morphological dynamics radiomic features, characterizing a lesion by ten sets of the same features with different values extracted from ten different thresholding results. Each nodule candidate was classified by a two-level classifier, including ten decision trees and a random forest, respectively. The CAD-MD algorithm was compared with a deep learning approach, the N-Net, using the UH dataset.
Results:
On the AL1 and AL2 of the UH dataset, the AUC of the AFROC curves were 0.777 and 0.851 for the CAD-MD algorithm and 0.478 and 0.472 for the N-Net, respectively. The CAD-MD algorithm achieved the sensitivities of 84.4% and 91.4% with 2.98 and 3.69 FPs/scan and the N-Net 74.4% and 80.7% with 3.90 and 4.49 FPs/scan, respectively. On the LIDC dataset, the CAD-MD algorithm attained the sensitivities of 87.6%, 89.2%, 92.2%, and 95.0% with 4 FPs/scan for AL1-AL4, respectively.
Conclusion:
The morphological dynamics radiomic features might serve as an effective set of radiomic features for lung nodule detection.
Key Points:
• Texture features varied with such CT system settings as reconstruction kernels of CT images, CT scanner models, and parameter settings, and so on. • Shape and first-order statistics were shown to be the most robust features against variation in CT imaging parameters. • The morphological dynamics radiomic features, which mainly characterized the dynamic patterns of morphological variation, were shown to be effective for lung nodule detection.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...