Validation of the infrared spectroscopy method for analysis of the composition of urine concretes
Related Experiment Video
Updated: Oct 7, 2025

Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
Published on: February 9, 2021
V I Smirnova1, S V Lapin1, D G Lebedev2,3
1Pavlov First Saint-Petersburg State Medical University.
Abstract:
The aim of this study was to validate the method for analyzing the composition of calculus using infrared (IR) spectroscopy by studying model mixtures of salts. Study was made with an ALPHA-P IR Fourier spectrometer with OPUS software (Bruker, Germany). The samples of pure chemical salts manufactured by Sigma-Aldrich USA were used to validate the method. Salt mixtures were prepared in ratios of 10/90, 50/50 and 90/10. To assess the effect of the fraction size on the calculus component results, were used calculi of patients with urolithiasis. For each mixture were used 10 repeated measurements. Analysis of the composition of model salts showed that in the study of pure cystine salt CV(%) was 0,79%, calcium carbonate - 0,92%, sodium urate - 0,97%, calcium oxalate monohydrate - 4,94%, magnesium ammonium phosphate - 5,59%. And the most common components were analyzed in the composition of complex mixtures, including 90%, 50% and 10% of the investigated component. Calcium oxalate monohydrate has CV(%) 5.70% in mixture 9 part of it to one part of impurities, in mixture 50/50 - 21.57% and in 10/90 - 5.70%. For uric acid in 90/10 - 2.20%, in 50/50 - 10.09%, in 10/90 - 31.94%. For calcium carbonate in 90/10 - 9.02%, in 50/50 - 11.98%, in 10/90 - 24.70%. The dispersion analysis showed that the weighed portions of salts with a particle diameter of more than 0.8 mm provide reproducibility with a CV - 11.48%, with a diameter of 0.2-0.8 mm - 5.35%, and finally less than 0.1 mm - 2.28%. The accuracy of the method is high, but the reproducibility of the IR-spectroscopy method is relatively low in the analysis of stones of mixed composition, due to the greater error in the determination of impurities. Laboratories should pay special attention to optimizing sample preparation to ensure particle fineness less than 0.1 mm.
More Related Videos
08:57Improving Infrared Spectroscopy Characterization of Soil Organic Matter with Spectral Subtractions
Published on: January 10, 2019
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Urine Studies I: Urinalysis
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Urine: Physical and Chemical Properties
The concentration of these solutes varies, with urea being the most abundant nitrogenous waste product. Other solutes include sodium, chloride, potassium, phosphate,...
Formation of Dilute Urine
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Formation of Concentrated Urine
Measurement of Air Content in Concrete
The pressure method,...