Related Experiment Video
Updated: Oct 6, 2025

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
An Unusual Presentation of Breast Implant Rupture
Anna Hudson1, Richard K J Brown, Satoshi Minoshima
1From the Department of Radiology and Imaging Sciences, University of Utah School of Medicine, Salt Lake City, UT.
Abstract:
A 99mTc-methylene diphosphate (MDP) bone scintigraphy scan was performed to follow up metastatic breast cancer. A circular region of radiotracer uptake in the location of the patient's left breast implant was seen. Review of the same-day chest CT and the prior CT showed that the patient's breast implant had ruptured in the interim. The 99mTc-MDP uptake in the capsule of the breast implant was attributed to rupture, likely secondary to inflammation. This is an example of an unusual presentation of breast implant rupture discovered on a 99mTc-MDP bone scintigraphy scan.