Test-retest reliability of mismatch negativity and gamma-band auditory steady-state response in patients with schizophrenia
Related Experiment Video
Updated: Oct 6, 2025

Transauricular Vagus Nerve Stimulation and Electroencephalographic Assessment in Disorders of Consciousness
Published on: July 11, 2025
Xiong Jiao1, Qiang Hu2, Yingying Tang3
1Shanghai Med-X Engineering Research Center, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China; Shanghai Key Laboratory of Psychotic Disorders, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.
Abstract:
Patients with schizophrenia show widespread impairments in clinical, cognitive and psychosocial functioning. Mismatch negativity (MMN) and gamma-band auditory steady-state response (ASSR) are two neurophysiological biomarkers widely used to inform diagnosis, guide treatments and track response to interventions in schizophrenia. However, evidence for the test-retest reliability of these indices across multiple sessions in schizophrenia patients remains scarce. In the present study, we included 34 schizophrenia patients (17 females) and obtained duration MMN (dMMN), frequency MMN (fMMN) and 40-Hz ASSR data across three sessions with intervals of 2 days. Event-related spectrum perturbation (ERSP) and inter-trial coherence (ITC) were calculated following Morlet wavelet time-frequency decomposition of ASSR data. The intra-class correlation coefficient (ICC) was used to quantify the reliability of MMN and ASSR measures among the three sessions. We found fair to good reliability for dMMN amplitudes but poor reliability for fMMN amplitudes. For the ASSR measures, ERSP showed good to excellent test-retest reliability while ITC had poor to fair test-retest reliability. In addition, the average of dMMN amplitudes was significantly correlated with that of ERSP across the three sessions. In summary, we established for the first time the short-term test-retest reliability of MMN and ASSR measures in schizophrenia patients. These findings demonstrate that dMMN amplitudes and ERSP of ASSR are reliable indices which may be used in longitudinal observational studies.
More Related Videos
05:33How to Calculate and Validate Inter-brain Synchronization in a fNIRS Hyperscanning Study
Published on: September 8, 2021
11:39Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
Published on: September 7, 2022