Related Experiment Video
Updated: Oct 6, 2025

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Mid-term outcomes of a stemless ceramic head anatomic total shoulder replacement
Maciej J K Simon1,2, Jennifer A Coghlan3,4, Jeff Hughes5
1Melbourne Shoulder and Elbow Centre, 1/80 Beach Road, Sandringham, VIC, 3191, Australia. maciej.simon@uksh.de.
Background:
In an anatomic shoulder replacement (aTSR) good results have been reported with the use of a stemless humeral prosthesis. In vitro a ceramic articulation with polyethylene has been shown to produce less polyethylene wear particles than with metal. This study aims to evaluate clinical and radiographic results of a stemless aTSR with a ceramic head articulating with a polyethylene glenoid component, with mid-term follow-up.
Methods:
All patients (n = 92) in this prospective study had an aTSR utilizing a stemless humeral component with a ceramic head and a cemented double pegged cemented polyethylene glenoid component for glenohumeral osteoarthritis. Pre- and postoperative clinical evaluations at 2 years were performed using the ASES score, Constant score, SPADI score, DASH score, VAS pain score, patient satisfaction and range of motion. There was a 5-year evaluation of SPADI, ASES, pain, and satisfaction, plus radiographic assessment of glenoid component radiolucent lines and humeral osteolysis.
Results:
Seventy-four cases (68.1 ± 7.1 years) had a five-year follow-up and demonstrated active elevation improvement from 91.3° preoperatively to 151.1° (p < 0.001). Further improvement was identified with the ASES from 41.6 to 94.3, the SPADI from 62.9 to 4.3, VAS pain from 5.6 to 0.4 (0-10), and satisfaction levels were at 96%. Sixty-two cases had no glenoid radiolucent lines with a maximum Lazarus score of 2 in one patient. Constant scores, available up to 2 years, improved significantly from 30.3 to 77.9 (p < 0.001). There was one case that required revision for glenoid loosening.
Conclusions:
Overall, the 5-year results of this ceramic head prosthesis demonstrated good radiographic and clinical outcomes.
Trial Registration:
ACTRN12613001183774 . Registered: 29 October 2013 - Retrospectively registered. Australian New Zealand Clinical Trials Registry (ANZCTR).