With the recent COVID-19 pandemic that has swept the world and the nation, hospitals around the country have experienced shortages in Personal Protective Equipment, specifically N95 filter face-mask respirators (FFRs). This has created the need for facilities to develop sterilization processes to enable reuse of face masks by the health care personnel. Among the various methods of sterilization, UVC light exposure is the easiest to implement given the factors of time, safety, and availability. Face masks and/or other PPE are exposed to UVC light for a specified time to kill any viruses or bacteria that may reside on the surfaces of the masks. A collaborative effort was formed in April of 2020 between Wellstar Health System and Kennesaw State University to (1) setup an appropriate sterilization room at a Wellstar hospital (2) develop the procedural guidelines necessary to ensure quality control and (3) assess employees' perceptions of the N95 FFR decontamination process and efficacy. This paper will first describe the methodology used to validate the layout of the room, which consists of a rudimentary analytical analysis of the UVC photon intensity from bulb-to-mask, computer simulations to determine the lighting power density throughout the room, and experimental measurements to confirm the appropriate energy deposition. This paper will then document the procedures for handling and processing the pre- and post-sterilized masks followed by employee survey findings. It is the hope of the authors that this paper will serve to provide a generic blueprint for hospitals and other organizations to follow if a future need arises for rapid UVC decontamination.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Handwashing I: Introduction and Types of Equipment
Hand wash basins in clinical areas should have faucets that can be turned on and off without using the hands; that is, they should be non-touch or lever-operated....
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...