Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Detection of Blood Glucose With Hemoglobin Content Using Compact Photonic Crystal Fiber.

IEEE transactions on nanobioscience·2021
Same author

Photonic Crystal Fiber-Based Reconfigurable Biosensor Using Phase Change Material.

IEEE transactions on nanobioscience·2021
Same author

Flexible autofocusing properties of ring Pearcey beams by means of a cross phase.

Optics letters·2020
Same author

Generation of novel partially coherent truncated Airy beams via Fourier phase processing.

Optics express·2020
Same author

Self-healing properties of Hermite-Gaussian correlated Schell-model beams.

Optics express·2020
Same author

Overview of Synthetic Methods to Prepare Plasmonic Transition-Metal Nitride Nanoparticles.

Chemistry (Weinheim an der Bergstrasse, Germany)·2020

Related Experiment Video

Updated: Oct 6, 2025

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
08:12

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

Published on: March 13, 2013

13.0K

Hollow-Core Microstructured Optical Fiber Based Refractometer: Numerical Simulation and Experimental Studies.

N Ayyanar, G Thavasi Raja, Skibina Y S

    IEEE Transactions on Nanobioscience
    |January 18, 2022
    PubMed
    Summary

    This study introduces a new type of optical fiber sensor designed to measure the refractive index of liquids. By filling the fiber's hollow center with a sample, researchers can detect changes in light transmission to identify substances like blood serum components. The device shows high sensitivity and potential for real-time medical or chemical testing.

    Keywords:
    photonic bandgapbiosensorspectral sensitivityrefractive index

    Frequently Asked Questions

    More Related Videos

    Fabrication and Testing of Microfluidic Optomechanical Oscillators
    09:10

    Fabrication and Testing of Microfluidic Optomechanical Oscillators

    Published on: May 29, 2014

    12.3K
    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    9.5K

    Related Experiment Videos

    Last Updated: Oct 6, 2025

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
    08:12

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

    Published on: March 13, 2013

    13.0K
    Fabrication and Testing of Microfluidic Optomechanical Oscillators
    09:10

    Fabrication and Testing of Microfluidic Optomechanical Oscillators

    Published on: May 29, 2014

    12.3K
    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    9.5K

    Area of Science:

    • Optics and photonics research within hollow-core microstructured optical fiber sensing
    • Biomedical engineering applications of refractive index sensors

    Background:

    No prior work had resolved the optimal configuration for high-sensitivity refractive index detection using specialized fiber geometries. Researchers often struggle to achieve precise measurements within narrow liquid analyte ranges. Existing optical tools frequently lack the necessary spectral resolution for complex biological samples. This gap motivated the development of advanced light-guiding structures. Prior research has shown that photonic bandgap effects can manipulate light propagation effectively. However, integrating these effects into practical, portable sensing platforms remains a significant challenge. That uncertainty drove the need for a robust, hollow-core design. Scientists continue to seek reliable methods for real-time monitoring of liquid properties in clinical settings.

    Purpose Of The Study:

    The aim of this research is to develop and validate a novel hollow-core microstructured optical fiber sensor for refractive index determination. The study addresses the need for high-sensitivity tools capable of analyzing liquid analytes in real-time. Researchers sought to overcome limitations in current sensing technologies by leveraging photonic bandgap effects. The team focused on creating a device that is both easy to operate and highly responsive to biological samples. This effort was motivated by the potential for improved diagnostic capabilities in medicine and chemistry. By exploring the relationship between transmission maxima and analyte indices, the authors intended to establish a reliable measurement framework. The project specifically targets the detection of substances with refractive indices near 1.33. This investigation provides a clear path toward practical applications in various scientific disciplines.

    Main Methods:

    The review approach involved a dual-track strategy combining computational modeling and physical laboratory testing. Investigators utilized numerical software to simulate light propagation through the specialized fiber geometry. They calculated the photonic bandgap behavior to predict transmission maxima shifts. The experimental phase required precise infiltration of liquid samples into the fiber core. Researchers prepared various plasma ratios from blood serum to test the device. They measured spectral responses using high-resolution optical equipment. The team compared the simulated data against the observed physical outcomes to ensure accuracy. This systematic process confirmed the sensor's operational parameters under controlled conditions.

    Main Results:

    Key findings from the literature show the sensor achieves a spectral sensitivity of 5636.3 nm/RIU. This high value indicates a strong response to small variations in the liquid refractive index. The device successfully detects indices within the range of 1.333 to 1.3385. These results were obtained by testing different plasma concentrations in blood serum. The data demonstrate that transmission maxima locations shift predictably as the analyte index changes. The researchers observed consistent performance during real-time monitoring trials. This sensitivity level allows for the detection of analytes with indices near 1.33. The findings confirm that the fiber structure effectively supports the intended sensing mechanism.

    Conclusions:

    The authors propose that their hollow-core design offers a viable path for sensitive liquid analyte detection. This study demonstrates that spectral shifts correlate directly with refractive index variations in blood serum. The researchers suggest that their device maintains high performance across a specific, narrow range of indices. Synthesis and implications indicate that the photonic bandgap mechanism provides a stable foundation for future biosensing platforms. The team notes that the ease of operation supports potential integration into existing medical diagnostic workflows. Their findings highlight the utility of this fiber geometry for identifying biomolecules in chemical environments. The authors conclude that real-time sensing capabilities represent a major advantage for practical laboratory applications. This work provides a framework for optimizing similar fiber-based sensors in diverse biological fields.

    The researchers propose a mechanism relying on the photonic bandgap effect. When liquid analytes fill the fiber core, the location of transmission maxima shifts, allowing for precise refractive index determination. This process enables the sensor to achieve a spectral sensitivity of 5636.3 nm/RIU.

    The device utilizes a hollow-core microstructured optical fiber. This specific architecture allows for the infiltration of liquid samples directly into the light-guiding region, which is necessary for interacting with the evanescent field and achieving the reported sensitivity levels.

    The fiber core must be filled with the liquid analyte to facilitate the photonic bandgap effect. This filling process is necessary because the transmission maxima depend on the refractive index of the material occupying the core, which dictates the light propagation characteristics.

    The researchers use numerical simulations to model light propagation and experimental studies to validate the sensor's performance. These combined approaches allow the team to correlate theoretical predictions with physical measurements obtained from blood serum samples.

    The sensor demonstrates a detection range between 1.333 and 1.3385 refractive index units. This measurement is specific to the analysis of different plasma ratios found within human blood serum samples tested during the experimental phase.

    The authors propose that the sensor has strong potential for medical, chemical, and biological applications. They suggest that the combination of high sensitivity and real-time monitoring capabilities makes the device suitable for future diagnostic tools.