Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Peripheral Venous Pressure Measurements to Evaluate Congestion in Heart Failure
Shiori Maruichi-Kawakami1, Kazuya Nagao2, Kenji Aida1
1Department of Cardiology, Cardiovascular Center, Osaka Red Cross Hospital, Osaka, Japan.
Background:
Accurate bedside assessment of congestion in the management of patients with heart failure remains challenging. As a continuous conduit of circulating fluid, systemic congestion represented by high right atrial pressure (RAP) may be reflected by peripheral venous pressure (PVP). We evaluated the reliability of PVP measurements for assessing congestion beyond conventional clinical assessments.
Methods And Results:
We performed conventional congestion assessments and PVP measurements in 95 patients undergoing pulmonary artery catheterization. PVP was measured via the 22-gauge peripheral venous access placed in the upper extremity. The median RAP and PVP was 7 (interquartile range [IQR]: 5-11) mmHg and 9 (IQR: 7-12) mmHg, respectively, with a mean bias of 1.8 ± 2.6 mmHg. PVP exhibited a strong linear correlation with RAP (Spearman R = 0.81; P < 0.001). PVP demonstrated greater discriminatory power for both RAP ≤ 8 mmHg (area under the curve [AUC]: 0.91 [95% confidence interval: 0.85-0.97]; sensitivity: 75%; specificity: 87%) and RAP > 12 mmHg (AUC: 0.98 [0.95-1.00]; sensitivity: 88%; specificity: 95%) than edema, jugular venous pressure, pulmonary congestion on chest radiograph, B-type natriuretic peptide levels, and inferior vena cava diameter.
Conclusions:
PVP measured via peripheral venous access strongly correlates with invasively obtained RAP. PVP measurements may improve current bedside assessments of congestion.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure