A Comparative Clinical Study of a Novel Pre-colonoscopy Bowel Capsule Preparation Against Two Commercially Available
Harriet Kingston-Smith1, Anoja W Gunaratne1, John Saxon1
1Centre for Digestive Diseases, Sydney, NSW, Australia.
Abstract:
Background and Aims: Colonoscopy surveillance depends on effective bowel preparation. Inadequate bowel preparation can lead to inaccurate clinical diagnosis, insufficient visualization of the colon and increased risk of missed diagnosis. This study aimed to compare the efficacy and safety of a novel Capsule Bowel Preparation (RitePrep), high-volume (2L) polyethylene glycol electrolyte solution (MoviPrep®) and low-volume (1L) polyethylene glycol electrolyte solution (Plenvu™). Methods: Patients (n = 120) were divided into three groups and were administered either RitePrep, MoviPrep® or Plenvu™ as a pre-colonoscopy bowel preparation followed by a colonoscopy at a single center. Validated Boston Bowel Preparation Score (BBPS) and bubble score were used to evaluate bowel cleanliness. Blood tests were also evaluated. The scores and the blood results were analyzed using Kruskal-Wallis and Chi-squared tests. Results: A total of 120 patients (median age of 55; 57 males) [RitePrep (n = 40), MoviPrep® (n = 40) and Plenvu™ (n = 40)] were included in the study. RitePrep was the most effective method for cleansing the bowel, with a significantly higher median BBPS compared to MoviPrep® and Plenvu™ (p = 0.006 and 0.024, respectively). Nearly 50% of the patients in Plenvu™ group showed increased serum osmolality disturbance. Nausea and vomiting were higher in Plenvu™ and MoviPrep® groups than RitePrep group. Conclusions: RitePrep was demonstrated to be a more effective and safe preparation than the other two preparations. RitePrep was not only well-tolerated by all patients; the preparation sufficiently cleared the ascending, transverse, and descending colon, enabling optimal visualization for the clinician. RitePrep was also much safer than the comparators, with no alteration in electrolytes measured. For both the clinician and the patient, RitePrep was the preferred preparation.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures II: Colonoscopy
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...