Activity of Ozonated Water in Sterilising and Disinfecting Dental Unit Water Pipelines System: A Comparative Study
Purpose:
A number of disinfectants and sanitisers are used in dentistry, and there are numerous commercial solutions available. Nonetheless, because each cleaning solution has its own set of indications and limits, there is no one-size-fits-all approach for processing all types of dental equipment. Functional water, such as electrolysed hypochlorite microbubbled water, efficiently eliminates and sterilises biofilms. The objective of the study was to evaluate whether ozonated water could be used to sterilise and disinfect dental-unit water pipelines (DUWP) that had been contaminated with micro-organisms, including Gram-positive and Gram-negative bacilli and cocci.
Materials And Methods:
Three different groups were formed: group A - ozonated water (Cantoosh); group B - 1% povidine iodine; and group C: conventional distilled water. Group A was the test group, group B the control group, and group C was the positive control group. The water sterilising system was replaced with the appropriate sterilising agent as per the allocated group classification, with 2 min of purging, so that the complete DUWP was filled with the water sterilising system. Samples were collected and analysed, along with a 2-min purge after 24 h, 7 days and 21 days, at the 3 outlet (OL) points: the 3-way syringe at the dental tray(OL1), the cup filler (OL2), and the 3-way syringe of the assistant zone (OL3). Repeated measures ANOVA was used to test for statistical significance between colony-forming units of control and experimental groups (p < 0.05).
Results:
The cup filler yielded higher counts than did the 3-way syringe at the dental tray (OL1) (6.40 and 8.05 on the log scale, respectively). A statistically significant difference in the CFUs was also observed between samples taken after 24 h vs 21 days between groups A, B and C.
Conclusion:
The findings showed that exposing DUWP tube systems to ozonated water for an extended length of time drastically lowered the number of microorganisms adhering to their surfaces.
More Related Videos
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...