Related Experiment Video
Updated: Oct 6, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Application of a Target-Guided Data Processing Approach in Saturated Peak Correction of GC×GC Analysis
Penghan Zhang1,2, Silvia Carlin1, Pietro Franceschi1
1Research and Innovation Center, Edmund Mach Foundation, Via E. Mach 1, San Michele all'Adige 38098, Italy.
Abstract:
Detector and column saturations are problematic in comprehensive two-dimensional gas chromatography (GC×GC) data analysis. This limits the application of GC×GC in metabolomics research. To address the problems caused by detector and column saturations, we propose a two-stage data processing strategy that will incorporate a targeted data processing and cleaning approach upstream of the "standard" untargeted analysis. By using the retention time and mass spectrometry (MS) data stored in a library, the annotation and quantification of the targeted saturated peaks have been significantly improved. After subtracting the nonperfected signals caused by saturation, peaks of coelutes can be annotated more accurately. Our research shows that the target-guided method has broad application prospects in the data analysis of GC×GC chromatograms of complex samples.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II