Self-Protected Virtual Sensor Network for Microcontroller Fault Detection
German Sternharz1, Jonas Skackauskas1, Ayman Elhalwagy1
1Department of Electronic and Electrical Engineering, College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge UB8 3PH, UK.
Sensors (Basel, Switzerland)
|January 22, 2022
Summary
This study presents a novel method using neural networks to assess electronic hardware integrity by comparing unit behavior to a reference. The approach effectively detects malfunctioning hardware, crucial for reliable device operation.
Area of Science:
- Electronics Engineering
- Artificial Intelligence
- Machine Learning
Background:
- Comparing functional behavior of individual electronic hardware units is essential for ensuring device integrity.
- Existing methods may not adequately capture the time-dependent nature of electronic hardware signals.
- The virtual sensor network (VSN) approach offers a framework for modeling physical system outputs.
Purpose of the Study:
- To introduce a procedure for comparing the functional behavior of individual electronic hardware units of the same type.
- To estimate the functional integrity of an unknown device unit by comparing it to a known reference unit.
- To extend the VSN approach using neural networks to model time-dependent electronic hardware behavior.
Main Methods:
- Utilized a virtual sensor network (VSN) approach.
- Employed a neural network (NN) with Long-Short-Term-Memory (LSTM) layers to model time-dependent functional behavior.
- Validated the method on measurements from a remote-controlled drone with reference and malfunctioning controller units.
Main Results:
- The proposed method successfully identified and described unexpected behavior in the malfunctioning controller unit.
- Achieved a signal sample prediction time of 0.14 ms.
- Obtained a reconstruction accuracy with a root mean square error (RMSE) below 0.04 relative to the data range.
Conclusions:
- The developed procedure effectively assesses the functional integrity of electronic hardware units.
- The integration of LSTM-based neural networks enhances the modeling of time-dependent signal behavior.
- Three self-protection features were introduced to quantify the certainty of the virtual sensor network model output.
Related Concept Videos
Radial System Protection
160
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
160
Line Protection with Impedance Relays
145
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
145
Zones of Protection
395
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
395
Overcurrent Relays
176
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
176
PI Controller: Design
572
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
572
Differential Relays
286
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
286