Related Experiment Video
Updated: Oct 5, 2025

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Dose-effect relationship between vaginal dose points and vaginal stenosis in cervical cancer: An EMBRACE-I sub-study
Henrike Westerveld1, Kathrin Kirchheiner2, Remi A Nout3
1Department of Radiation Oncology, Amsterdam University Medical Centers, Cancer Center Amsterdam, University of Amsterdam, the Netherlands.
Background And Purpose:
To evaluate dose-effect relationships between vaginal dose points and vaginal stenosis in patients treated for locally advanced cervical cancer with radio(chemo)therapy and image-guided adaptive brachytherapy.
Material And Methods:
Patients from six centres participating in the EMBRACE-I study were included. Information on doses to different vaginal dose points, including the Posterior-Inferior Border of Symphysis (PIBS) points and recto-vaginal reference (RV-RP) point, were retrieved from the treatment planning system. In addition, the vaginal reference length (VRL) was evaluated. Vaginal stenosis was prospectively assessed according to the CTCAEv3.0 system at baseline and follow-up. Primary endpoint was grade 2 or higher (G ≥ 2) vaginal stenosis. Impact of dose to the vaginal dose points, and impact of VRL, age, vaginal involvement and applicator on vaginal stenosis G ≥ 2 was evaluated with a Cox proportional-hazard regression model.
Results:
301 patients were included. Median follow-up was 49 months. During follow-up, the incidence of G0, G1, G2, and G3 vaginal stenosis was 25% (76), 52% (158), 20% (59) and 3% (8), respectively. Median total doses to PIBS+2 cm, PIBS, PIBS-2 cm and the RV-RP were 52.9 (IQR 49.3-64.7), 41.0 (IQR 15.4-49.0), 4.1 (IQR 2.9-7.0) and 64.6 (IQR 60.0-70.6) Gy EQD23, respectively. Higher doses to the PIBS, PIBS + 2 cm and RV-RP points were significantly associated with increased risk for vaginal stenosis G ≥ 2. Other risk factors for vaginal stenosis were: vaginal involvement at diagnosis, higher age, shorter VRL and use of a tandem-ovoid applicator.
Conclusion:
Higher doses to the PIBS+2 cm, PIBS and RV-RP dose points are associated with vaginal stenosis G ≥ 2.
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Dose-Response Relationship: Overview
Dose-Response Relationship: Potency and Efficacy
Bioavailability Study Design: Single Versus Multiple Dose Studies
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Dose-Response Relationship: Selectivity and Specificity