Related Experiment Video
Updated: Oct 5, 2025

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Evaluation of the annual occupational effective doses in a SPECT/CT department
Ali Aamry1, Abdelmoneim Sulieman2, N Tamam3
1Nuclear Medicine Department, King Saud Medical City (KSMC), Riyadh, Saudi Arabia.
Abstract:
Staff occupational radiation exposure is limited to 20 mSv annually to preclude tissue reaction and lower risk of cancer effect. Staff occupational exposure arises during the preparation, injection, and scanning of the patients. Recent studies reported that nuclear medicine personnel might exceed the annual dose limit in high workload and poor radiation protection circumstances. Therefore, an accurate estimation of the annual dose limit is recommended. The goal of this research is to calculate the cumulative external effective dose (mSv) per year for nuclear medicine physicians, technologists, and nurses at SPECT/CT department. A total of 15 staff worked in the nuclear medicine department at King Saud Medical City (KSMC), Riyadh, Saudi Arabia were evaluated for the last six years. 99mTc is used more frequently for most of the patients. The procedures include renal, cardiac scintigraphy procedures. Staff dose was quantified using calibrated thermoluminecnt dosimeters (TLD-100) with an automatic TLD reader (Harshaw 6600). Exposure to ionizing radiation was evaluated in terms of deep doses (Hp(10) were evaluated. The overall average and standard deviation of the external doses for nuclear medicine physicians, technologists' and nurses were 1.8 ± 0.7, 1.9 ± 0.6, 2.0 ± 0.9, 2.2 ± 0.8, 6.0 ± 2.8, and 3.6 ± 1.3 for the years 2015,2016,2017,2018,2019, and 2020, respectively. Technologists and nurses received higher doses of compared to the nuclear medicine physicians. Technologists and nurses involved in radionuclide preparation, patients' injection, and image acquisition. Staff annual exposure is below the annual dose limits; however, this external dose is considered high compared to the current workload.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...