Related Experiment Video
Updated: Oct 5, 2025

Operation of a 25 KWth Calcium Looping Pilot-plant with High Oxygen Concentrations in the Calciner
Published on: October 25, 2017
Successful startup of the single-stage PN-A (partial nitrification-anammox) process by controlling the oxygen supply
Lianze Yu1, Chi Zhang1, Miao Zhang1
1School of Environmental Engineering and Science, Yangzhou University, 196 West Huayang Road, Yangzhou, 225127, Jiangsu, China.
Abstract:
The single PN-A (partial nitrification-anammox) reactor offers a cost-effective solution for nitrogen removal. However, optimal control of the PN-A reactor is challenging due to the interactive mechanisms among the oxygen supply, bulk liquid DO (dissolved oxygen) concentration, and the balance of various functional bacterial species. In this study, a mathematical model was used to derive the optimal control variable for the maximum nitrogen removal, and an experimental PN-A reactor was operated to verify the model simulation results. The model simulation results indicate that the oxygen supply to the ammonium load ratio is the key factor to control the single-stage PN-A reactor for optimal TN removal. For optimal TN removal, the oxygen supply to the ammonium load ratio should be 1.9 mg O2/mg N. The DO concentration is not the key control parameter to get the maximum TN removal as the optimal TN removal could be achieved under a wide range of DO concentration. The model simulation results were verified in the experimental PN-A reactor under oxygen transfer rate ([Formula: see text]) at 52 day-1, HRT at 24 h, and ammonium load ratio of 0.55 kg N/(m3∙day).