Objectives:
To evaluate the diagnostic value of computer-aided diagnosis (CAD) software on ultrasound in distinguishing benign and malignant breast masses and avoiding unnecessary biopsy.
Methods:
This prospective, multicenter study included patients who were scheduled for pathological diagnosis of breast masses between April 2019 and November 2020. Ultrasound images, videos, CAD analysis, and BI-RADS were obtained. The AUC, accuracy, sensitivity, specificity, PPV, and NPV were calculated and compared with radiologists.
Results:
Overall, 901 breast masses in 901 patients were enrolled in this study. The accuracy, sensitivity, specificity, PPV and NPV of CAD software were 89.6%, 94.2%, 87.0%, 80.4%, and 96.3, respectively, in the long-axis section; 89.0%, 91.4%, 87.7%, 80.8%, and 94.7%, respectively, in the short-axis section. With BI-RADS 4a as the cut-off value, CAD software has a higher AUC (0.906 vs 0.734 vs 0.696, all p < 0.001) than both experienced and less experienced radiologists. With BI-RADS 4b as the cut-off value, CAD software showed better AUC than less experienced radiologists (0.906 vs 0.874, p < 0.001), but not superior to experienced radiologists (0.906 vs 0.883, p = 0.057). After the application of CAD software, the unnecessary biopsy rate of BI-RADS categories 4 and 5 was significantly decreased (33.0% vs 11.9%, 37.8% vs 14.5%), and the malignant rate of biopsy in category 4a was significantly increased (11.6% vs 40.7%, 7.4% vs 34.9%, all p < 0.001).
Conclusions:
CAD software on ultrasound can be used as an effective auxiliary diagnostic tool for differential diagnosis of benign and malignant breast masses and reducing unnecessary biopsy.
Clinical Trial Registration:
ClinicalTrials.gov (NCT03887598) KEY POINTS: • Prospective multicenter study showed that computer-aided diagnosis software provides greater diagnostic confidence for differentiating benign and malignant breast masses. • Computer-aided diagnosis software can help radiologists reduce unnecessary biopsy. • The management of patients with breast masses becomes more appropriate.